• Post author:
  • Post category:Blog
  • Reading time:111 mins read
  • Post last modified:June 12, 2024

3.4.6 Packet Tracer – Configure VLANs and Trunking – Physical Mode Answers Full 100% 2023 2024

This is Cisco 3.4.6 Packet Tracer – Configure VLANs and Trunking – Physical Mode Answers Full 100% 2023 2024 for Cisco CCNA 2 v7 SRWE v7.02.

Packet Tracer – Configure VLANs and Trunking – Physical Mode (Answers Version)

Answers Note: Red font color or gray highlights indicate text that appears in the Answers copy only.

Topology

This topology has 2 PCs and 2 switches. PC-a is connected to S1 F0/6. S1 F0/1 is connected S2 F0/1. S2 F0/18 is connected PC-b.

Addressing Table

Device

Interface

IP Address

Subnet Mask

Default Gateway

S1

VLAN 1

192.168.1.11

255.255.255.0

N/A

S2

VLAN 1

192.168.1.12

255.255.255.0

N/A

PC-A

NIC

192.168.10.3

255.255.255.0

192.168.10.1

PC-B

NIC

192.168.10.4

255.255.255.0

192.168.10.1

Blank Line – no additional information

Objectives

Part 1: Build the Network and Configure Basic Device Settings

Part 2: Create VLANs and Assign Switch Ports

Part 3: Maintain VLAN Port Assignments and the VLAN Database

Part 4: Configure an 802.1Q Trunk Between the Switches

Background / Scenario

Modern switches use virtual local-area networks (VLANs) to improve network performance by separating large Layer 2 broadcast domains into smaller ones. VLANs can also be used as a security measure by controlling which hosts can communicate. In general, VLANs make it easier to design a network to support the goals of an organization.

VLAN trunks are used to span VLANs across multiple devices. Trunks allow the traffic from multiple VLANS to travel over a single link, while keeping the VLAN identification and segmentation intact.

In this Packet Tracer Physical Mode (PTPM) activity, you will create VLANs on both switches in the topology, assign VLANs to switch access ports, and verify that VLANs are working as expected. You will then create a VLAN trunk between the two switches to allow hosts in the same VLAN to communicate through the trunk, regardless of which switch to which the host is attached.

Instructions

Part 1:Build the Network and Configure Basic Device Settings

In Part 1, you will set up the network topology and configure basic settings on the PC hosts and switches.

Step 1:Build the network as shown in the topology.

Attach the devices as shown in the topology diagram, and cable as necessary.

  1. Click and drag both switch S1 and S2 to the Rack.

Note: This activity will open with 37% completion because the switch ports are all shutdown. When you install the switches in the rack, the ports will automatically be activated. After about a minute, the score will drop to 1%. Later in the activity, you will shut down unused ports.

  1. Click and drag both PC-A and PC-B to the Table and use the power button to turn them on.
  2. Provide network connectivity by connecting Copper Straight-through cables, as shown in the topology.
  3. Connect Console Cable from device PC-A to S1 and from device PC-B to S2.

Step 2:Configure basic settings for each switch.

  1. From the Desktop Tab on each PC, use the Terminal to console into each switch and enable privileged EXEC mode.

Open configuration window

Switch> enable

  1. Enter configuration mode.

Switch# config terminal

  1. Assign a device name to each switch.

Switch(config)# hostname S1

Switch(config)# hostname S2

  1. Assign class as the privileged EXEC encrypted password.

S1(config)# enable secret class

S2(config)# enable secret class

  1. Assign cisco as the console password and enable login.

S1(config)# line console 0

S1(config-line)# password cisco

S1(config-line)# login

S2(config)# line console 0

S2(config-line)# password cisco

S2(config-line)# login

  1. Assign cisco as the vty password and enable login.

S1(config)# line vty 0 4

S1(config-line)# password cisco

S1(config-line)# login

S2(config)# line vty 0 4

S2(config-line)# password cisco

S2(config-line)# login

  1. Encrypt the plaintext passwords.

S1(config)# service password-encryption

S2(config)# service password-encryption

  1. Create a banner that warns anyone accessing the device that unauthorized access is prohibited.

S1(config)# banner motd $ Authorized Users Only! $

S2(config)# banner motd $ Authorized Users Only! $

  1. Configure the IP address listed in the Addressing Table for VLAN 1 on the switch.

Note: The VLAN 1 address is not grade because you will remove it later in the activity. However, you will need VLAN 1 to test connectivity later in this Part.

S1(config)# interface vlan 1

S1(config-if)# ip address 192.168.1.11 255.255.255.0

S1(config-if)# no shutdown

S1(config-if)# exit

S2(config)# interface vlan 1

S2(config-if)# ip address 192.168.1.12 255.255.255.0

S2(config-if)# no shutdown

S2(config-if)# exit

  1. Shut down all interfaces that will not be used.

S1(config)# interface range f0/2-5, f0/7-24, g0/1-2

S1(config-if-range)# shutdown

S1(config-if-range)# exit

S1(config)# exit

S2(config)# interface range f0/2-17, f0/19-24, g0/1-2

S2(config-if-range)# shutdown

S2(config-if-range)# exit

S2(config)# exit

  1. Set the clock on each switch.

Note: The clock setting cannot be graded in Packet Tracer.

S1# clock set 15:30:00 19 August 2021

S2# clock set 15:30:00 19 August 2021

  1. Save the running configuration to the startup configuration file.

S1# copy running-config startup-config

S2# copy running-config startup-config

Close configuration window

Step 3:Configure PC hosts.

From the Desktop tab on each PC, click IP Configuration and enter the addressing information as displayed in the Addressing Table.

Step 4:Test connectivity.

Test network connectivity by attempting to ping between each of the cabled devices.

Questions:

Can PC-A ping PC-B?

Type your answers here.

Yes

Can PC-A ping S1?

Type your answers here.

No

Can PC-B ping S2?

Type your answers here.

No

Open configuration window

Can S1 ping S2?

Type your answers here.

Yes

If you answered no to any of the above questions, why were the pings unsuccessful?

Type your answers here.

Pings were unsuccessful when trying to ping a device on a different subnet. For those pings to be successful, a default gateway must exist to route traffic from one subnet to another.

Close configuration window

Part 2:Create VLANs and Assign Switch Ports

In Part 2, you will create Management, Operations, Parking_Lot, and Native VLANs on both switches. You will then assign the VLANs to the appropriate interface. The show vlan command is used to verify your configuration settings.

Step 1:Create VLANs on the switches.

From the Desktop Tab on each PC, use Terminal to continue configuring both network switches.

Open configuration window

  1. Create the VLANs on S1.

S1(config)# vlan 10

S1(config-vlan)# name Operations

S1(config-vlan)# vlan 20

S1(config-vlan)# name Parking_Lot

S1(config-vlan)# vlan 99

S1(config-vlan)# name Management

S1(config-vlan)# vlan 1000

S1(config-vlan)# name Native

S1(config-vlan)# end

  1. Create the same VLANs on S2.
  2. Issue the show vlan brief command to view the list of VLANs on S1.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/6, Fa0/7, Fa0/8

Fa0/9, Fa0/10, Fa0/11, Fa0/12

Fa0/13, Fa0/14, Fa0/15, Fa0/16

Fa0/17, Fa0/18, Fa0/19, Fa0/20

Fa0/21, Fa0/22, Fa0/23, Fa0/24

Gi0/1, Gi0/2

10Operationsactive

20Parking_Lotactive

99Managementactive

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Questions:

What is the default VLAN?

Type your answers here.

VLAN 1

What ports are assigned to the default VLAN?

Type your answers here.

All switch ports are assigned to VLAN 1 by default.

Step 2:Assign VLANs to the correct switch interfaces.

  1. Assign VLANs to the interfaces on S1.

1)Assign PC-A to the Operation VLAN.

S1(config)# interface f0/6

S1(config-if)# switchport mode access

S1(config-if)# switchport access vlan 10

2)From VLAN 1, remove the management IP address and configure it on VLAN 99.

S1(config)# interface vlan 1

S1(config-if)# no ip address

S1(config-if)# interface vlan 99

S1(config-if)# ip address 192.168.1.11 255.255.255.0

S1(config-if)# end

  1. Issue the show vlan brief command and verify that the VLANs are assigned to the correct interfaces.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Fa0/11, Fa0/12, Fa0/13

Fa0/14, Fa0/15, Fa0/16, Fa0/17

Fa0/18, Fa0/19, Fa0/20, Fa0/21

Fa0/22, Fa0/23, Fa0/24, Gi0/1

Gi0/2

10OperationsactiveFa0/6

20Facultyactive

99Managementactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

  1. Issue the show ip interface brief command.

S1# show ip interface brief

InterfaceIP-AddressOK? Method StatusProtocol

Vlan1unassignedYES unsetupup

Vlan99192.168.1.11YES manual updown

FastEthernet0/1unassignedYES unsetupup

FastEthernet0/2unassignedYES unsetadministratively down down

FastEthernet0/3unassignedYES unsetadministratively down down

FastEthernet0/4unassignedYES unsetadministratively down down

FastEthernet0/5unassignedYES unsetadministratively down down

FastEthernet0/6unassignedYES unsetupup

FastEthernet0/7unassignedYES unsetadministratively down down

<output omitted>

Question:

What is the status of VLAN 99? Explain.

Type your answers here.

The status of VLAN 99 is up/down, up because the VLAN exists in the database but down because the VLAN has not been assigned to an active port yet.

  1. Assign PC-B to the Operations VLAN on S2.

S2(config)# interface f0/18

S2(config-if)# switchport mode access

S2(config-if)# switchport access vlan 10

  1. From VLAN 1, remove the management IP address and configure it on VLAN 99 according to the Addressing Table .

S2(config)# interface vlan 1

S2(config-if)# no ip address

S2(config-if)# interface vlan 99

S2(config-if)# ip address 192.168.1.12 255.255.255.0

  1. Use the show vlan brief command to verify that the VLANs are assigned to the correct interfaces.

S2# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/6, Fa0/7, Fa0/8

Fa0/9, Fa0/10, Fa0/11, Fa0/12

Fa0/13, Fa0/14, Fa0/15, Fa0/16

Fa0/17, Fa0/19, Fa0/20, Fa0/21

Fa0/22, Fa0/23, Fa0/24, Gi0/1

Gi0/2

10OperationsactiveFa0/18

20Parking_Lotactive

99Managementactive

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Questions:

Is S1 able to ping S2? Explain.

Type your answers here.

No. The IP addresses for the switches now reside in VLAN 99. VLAN 99 traffic will not be sent over interface F0/1.

Close configuration window

Is PC-A able to ping PC-B? Explain.

Type your answers here.

No. Interface F0/1 is not assigned to VLAN 10, so VLAN 10 traffic will not be sent over it.

Part 3:Maintain VLAN Port Assignments and the VLAN Database

In Part 3, you will change port VLAN assignments and remove VLANs from the VLAN database.

Step 1:Assign a VLAN to multiple interfaces.

From the Desktop Tab on each PC, use Terminal to continue configuring both network switches.

Open configuration window

  1. On S1, assign interfaces F0/11 – 24 to VLAN99.

S1(config)# interface range f0/11-24

S1(config-if-range)# switchport mode access

S1(config-if-range)# switchport access vlan 99

S1(config-if-range)# end

  1. Issue the show vlan brief command to verify VLAN assignments.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Gi0/1, Gi0/2

10OperationsactiveFa0/6

20Parking_Lotactive

99ManagementactiveFa0/11, Fa0/12, Fa0/13, Fa0/14

Fa0/15, Fa0/16, Fa0/17, Fa0/18

Fa0/19, Fa0/20, Fa0/21, Fa0/22

Fa0/23, Fa0/24

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

  1. Reassign F0/11 and F0/21 to VLAN 10.

S1(config)# interface range f0/11, f0/21

S1(config-if-range)# switchport access vlan 10

S1(config-if-range)# end

  1. Verify that VLAN assignments are correct.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23, Fa0/24

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Step 2:Remove a VLAN assignment from an interface.

  1. Use the no switchport access vlan command to remove the VLAN 99 assignment to F0/24.

S1(config)# interface f0/24

S1(config-if)# no switchport access vlan

S1(config-if)# end

  1. Verify that the VLAN change was made.

Question:

Which VLAN is F0/24 now associated with?

Type your answers here.

VLAN 1, the default VLAN.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Fa0/24, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Step 3:Remove a VLAN ID from the VLAN database.

  1. Add VLAN 30 to interface F0/24 without issuing the global VLAN command.

S1(config)# interface f0/24

S1(config-if)# switchport access vlan 30

% Access VLAN does not exist. Creating vlan 30

Note: Current switch technology no longer requires that the vlan command be issued to add a VLAN to the database. By assigning an unknown VLAN to a port, the VLAN will be created and added to the VLAN database.

  1. Verify that the new VLAN is displayed in the VLAN table.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

30VLAN0030activeFa0/24

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Question:

What is the default name of VLAN 30?

Type your answers here.

VLAN0030

  1. Use the no vlan 30 command to remove VLAN 30 from the VLAN database.

S1(config)# no vlan 30

S1(config)# end

  1. Issue the show vlan brief command. F0/24 was assigned to VLAN 30.

Question:

After deleting VLAN 30 from the VLAN database, why is F0/24 no longer displayed in the output of the show vlan brief command? What VLAN is port F0/24 now assigned to? What happens to the traffic destined to the host that is attached to F0/24?

Type your answers here.

When you delete a VLAN, any ports assigned to that VLAN become inactive. Port F0/24 is still associated to VLAN 30 but is no longer shown in the output. VLAN 30 is now inactive because it does not exist in the VLAN database. Any port associated with VLAN 30 will not transfer any traffic.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

  1. On interface F0/24, issue the no switchport access vlan command.

S1(config)# interface f0/24

S1(config-if)# no switchport access vlan

S1(config-if)# end

  1. Issue the show vlan brief command to determine the VLAN assignment for F0/24.

Questions:

To which VLAN is F0/24 assigned?

Type your answers here.

The default VLAN, VLAN 1

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/1, Fa0/2, Fa0/3, Fa0/4

Fa0/5, Fa0/7, Fa0/8, Fa0/9

Fa0/10, Fa0/24, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

Note: Before removing a VLAN from the database, it is recommended that you reassign all the ports assigned to that VLAN.

Why should you reassign a port to another VLAN before removing the VLAN from the VLAN database?

Type your answers here.

The interfaces assigned to a VLAN that is the removed from the VLAN database become inactive and are unavailable for use until they are reassigned to another VLAN. This can be a tricky thing to troubleshoot as trunked interfaces do not show up in the port list as well (Part 4 contains more information about trunked interfaces).

Part 4:Configure an 802.1Q Trunk Between the Switches

In Part 4, you will configure interface F0/1 to use the Dynamic Trunking Protocol (DTP) to allow it to negotiate the trunk mode. After this has been accomplished and verified, you will disable DTP on interface F0/1 and manually configure it as a trunk.

Step 1:Use DTP to initiate trunking on F0/1.

The default DTP mode of a 2960 switch port is dynamic auto. This allows the interface to convert the link to a trunk if the neighboring interface is set to trunk or dynamic desirable mode.

Open configuration window

  1. On S1, set F0/1 to negotiate trunk mode.

S1(config)# interface f0/1

S1(config-if)# switchport mode dynamic desirable

Sep 19 02:51:47.257: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up

Sep 19 02:51:47.291: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan99, changed state to up

You should also receive link status messages on S2.

S2#

Sep 19 02:42:19.424: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up

Sep 19 02:42:21.454: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan99, changed state to up

Sep 19 02:42:22.419: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up

  1. On S1 and S2, issue the show vlan brief command. Interface F0/1 is no longer assigned to VLAN 1. Trunked interfaces are not listed in the VLAN table.

S1# show vlan brief

VLAN NameStatusPorts

—- ——————————– ——— ——————————-

1defaultactiveFa0/2, Fa0/3, Fa0/4, Fa0/5

Fa0/7, Fa0/8, Fa0/9, Fa0/10

Fa0/24, Gi0/1, Gi0/2

10OperationsactiveFa0/6, Fa0/11, Fa0/21

20Parking_Lotactive

99ManagementactiveFa0/12, Fa0/13, Fa0/14, Fa0/15

Fa0/16, Fa0/17, Fa0/18, Fa0/19

Fa0/20, Fa0/22, Fa0/23

1000 Nativeactive

1002 fddi-defaultactive

1003 token-ring-defaultactive

1004 fddinet-defaultactive

1005 trnet-defaultactive

  1. Issue the show interfaces trunk command to view trunked interfaces. Notice that the mode on S1 is set to desirable, and the mode on S2 is set to auto.

S1# show interfaces trunk

PortModeEncapsulationStatusNative vlan

Fa0/1desirablen-802.1qtrunking1

PortVlans allowed on trunk

Fa0/11-1005

PortVlans allowed and active in management domain

Fa0/11,10,20,99,1000

PortVlans in spanning tree forwarding state and not pruned

Fa0/11,10,20,99,1000

S2# show interfaces trunk

PortModeEncapsulationStatusNative vlan

Fa0/1auton-802.1qtrunking1

PortVlans allowed on trunk

Fa0/11-1005

PortVlans allowed and active in management domain

Fa0/11,10,20,99,1000

PortVlans in spanning tree forwarding state and not pruned

Fa0/11,10,20,99,1000

Note: By default, all VLANs are allowed on a trunk. The switchport trunk command allows you to control what VLANs have access to the trunk. For this activity, keep the default settings. This allows all VLANs to traverse F0/1.

Close configuration window

  1. Verify that VLAN traffic is traveling over trunk interface F0/1.

Questions:

Can S1 ping S2?

Type your answers here.

Yes

Can PC-A ping PC-B?

Type your answers here.

Yes

Can PC-A ping S1?

Type your answers here.

No

Can PC-B ping S2?

Type your answers here.

No

If you answered no to any of the above questions, explain below.

Type your answers here.

The switches are in VLAN 99 and the PCs are in VLAN 10; therefore, the pings between VLANs were unsuccessful.

Step 2:Manually configure trunk interface F0/1.

The switchport mode trunk command is used to manually configure a port as a trunk. This command should be issued on both ends of the link.

  1. On interface F0/1, change the switchport mode to force trunking. Make sure to do this on both switches.

Open configuration window

S1(config)# interface f0/1

S1(config-if)# switchport mode trunk

S2(config)# interface f0/1

S2(config-if)# switchport mode trunk

  1. Issue the show interfaces trunk command to view the trunk mode. Notice that the mode changed from desirable to on.

S1# show interfaces trunk

PortModeEncapsulationStatusNative vlan

Fa0/1on802.1qtrunking1

PortVlans allowed on trunk

Fa0/11-1005

PortVlans allowed and active in management domain

Fa0/11,10,20,99,1000

PortVlans in spanning tree forwarding state and not pruned

Fa0/11,10,20,99,1000

  1. Modify the trunk configuration on both switches by changing the native VLAN from VLAN 1 to VLAN 1000.

S1(config)# interface f0/1

S1(config-if)# switchport trunk native vlan 1000

S2(config)# interface f0/1

S2(config-if)# switchport trunk native vlan 1000

  1. Issue the show interfaces trunk command to view the trunk. Notice the Native VLAN information is updated.

S2# show interfaces trunk

PortModeEncapsulationStatusNative vlan

Fa0/1on802.1qtrunking1000

PortVlans allowed on trunk

Fa0/11-1005

PortVlans allowed and active in management domain

Fa0/11,10,20,99,1000

PortVlans in spanning tree forwarding state and not pruned

Fa0/11,10,20,99,1000

Questions:

Why might you want to manually configure an interface to trunk mode instead of using DTP?

Type your answers here.

Not all equipment uses DTP. DTP is Cisco proprietary and using the switchport mode trunk command ensures that the port will become a trunk no matter what type of equipment is connected to the other end of the link.

Why might you want to change the native VLAN on a trunk?

Type your answers here.

Using VLAN 1, the default VLAN, as the native VLAN is a security risk. All the different control protocols that are exchanged between switches are exchanged via the native VLAN 1 untagged, and that information could be exposed if default settings are used on ports that users connect to.

Close configuration window

Reflection Questions

  1. What is needed to allow hosts on VLAN 10 to communicate to hosts on VLAN 99?

Type your answers here.

Answers will vary, but to allow Inter-VLAN routing requires a Layer 3 device is needed to route traffic between VLANs.

  1. What are some primary benefits that an organization can receive through effective use of VLANs?

Type your answers here.

Answers will vary, but VLAN benefits include: better security, cost savings (efficient use of bandwidth and uplinks), higher performance (smaller broadcast domains), broadcast storm mitigation, improved IT staff efficiency, simpler project and application management.

Subscribe
Notify of
guest
0 Comments
Newest
Oldest Most Voted
Inline Feedbacks
View all comments