11.6.1 Packet Tracer – Switch Security Configuration Answers

Packet Tracer – Switch Security Configuration (Answers Version)

Answers Note: Red font color or gray highlights indicate text that appears in the instructor copy only.

VLAN Table

Switch

VLAN Number

VLAN Name

Port Membership

Network

SW-1

10

Admin

F0/1, F0/2

192.168.10.0/24

SW-1

20

Sales

F0/10

192.168.20.0/24

SW-1

99

Management

F0/24

192.168.99.0/24

SW-1

100

Native

G0/1, G0/2

None

SW-1

999

BlackHole

All unused

None

SW-2

10

Admin

F0/1, F0/22

192.168.10.0/24

SW-2

20

Sales

F0/10

192.168.20.0/24

SW-2

99

Management

F0/24

192.168.99.0/24

SW-2

100

Native

None

None

SW-2

999

BlackHole

All unused

None

Objectives

Part 1: Create a Secure Trunk

Part 2: Secure Unused Switchports

Part 3: Implement Port Security

Part 4: Enable DHCP Snooping

Part 5: Configure Rapid PVST PortFast and BPDU Guard

Background

You are enhancing security on two access switches in a partially configured network. You will implement the range of security measures that were covered in this module according to the requirements below. Note that routing has been configured on this network, so connectivity between hosts on different VLANs should function when completed.

Instructions

Step 1:Create a Secure Trunk.

  1. Connect the G0/2 ports of the two access layer switches.
  2. Configure ports G0/1 and G0/2 as static trunks on both switches.
  3. Disable DTP negotiation on both sides of the link.
  4. Create VLAN 100 and give it the name Native on both switches.
  5. Configure all trunk ports on both switches to use VLAN 100 as the native VLAN.

Step 2:Secure Unused Switchports.

  1. Shutdown all unused switch ports on SW-1.
  1. On SW-1, create a VLAN 999 and name it BlackHole. The configured name must match the requirement exactly.
  2. Move all unused switch ports to the BlackHole VLAN.

Step 3:Implement Port Security.

  1. Activate port security on all the active access ports on switch SW-1.
  1. Configure the active ports to allow a maximum of 4 MAC addresses to be learned on the ports.
  2. For ports F0/1 on SW-1, statically configure the MAC address of the PC using port security.
  3. Configure each active access port so that it will automatically add the MAC addresses learned on the port to the running configuration.
  4. Configure the port security violation mode to drop packets from MAC addresses that exceed the maximum, generate a Syslog entry, but not disable the ports.

Step 4:Configure DHCP Snooping.

  1. Configure the trunk ports on SW-1 as trusted ports.
  1. Limit the untrusted ports on SW-1 to five DHCP packets per second.
  2. On SW-2, enable DHCP snooping globally and for VLANs 10, 20 and 99.

Note: The DHCP snooping configuration may not score properly in Packet Tracer.

Step 5:Configure PortFast, and BPDU Guard.

  1. Enable PortFast on all the access ports that are in use on SW-1.
  1. Enable BPDU Guard on all the access ports that are in use on SW-1.
  2. Configure SW-2 so that all access ports will use PortFast by default.

End of document

SW1 Configurations

enable

configure terminal

spanning-tree portfast default

interface FastEthernet0/1

ip dhcp snooping limit rate 5

switchport mode access

switchport port-security

switchport port-security maximum 4

switchport port-security mac-address sticky

switchport port-security violation restrict

switchport port-security mac-address 0010.11E8.3CBB

spanning-tree portfast

spanning-tree bpduguard enable

!

interface range FastEthernet0/2, FastEthernet0/10,FastEthernet0/24

ip dhcp snooping limit rate 5

switchport mode access

switchport port-security

switchport port-security maximum 4

switchport port-security mac-address sticky

switchport port-security violation restrict

spanning-tree portfast

spanning-tree bpduguard enable

!

interface range FastEthernet0/3 – 9, FastEthernet0/11 – 23

switchport access vlan 999

shutdown

!

interface range GigabitEthernet0/1 – 2

switchport trunk native vlan 100

ip dhcp snooping trust

switchport mode trunk

switchport nonegotiate

vlan 100

name Native

vlan 999

name BlackHole

SW-2 Configuration

enable

configure terminal

ip dhcp snooping

ip dhcp snooping vlan 10,20,99

spanning-tree portfast default

interface GigabitEthernet0/1

switchport trunk native vlan 100

switchport mode trunk

switchport nonegotiate

!

interface GigabitEthernet0/2

switchport trunk native vlan 100

switchport mode trunk

switchport nonegotiate

Subscribe
Notify of
guest
0 Comments
Newest
Oldest Most Voted
Inline Feedbacks
View all comments