H13-629 : HCIE-Storage : Part 05
-
By which of the following technologies can vmware VDI reduce the storage space used by the virtual desktop system?
- View storage accelerator (VSA)
- Persona management
- Link cloning
- SE sparse virtual disk
-
If a customer needs to install the simpana file system using the backup client on the production system server, which of the following configuration is essential? (Multiple choice.)
- In the backup client Tianjin ah master server resolution.
- Add a resolution of the media server on the backup client.
- When the master server adds the resolution of the backup client.
- Add a resolution of the storage media to the media server.
-
Users use vsphere 5.5 to build business virtualization. In the course of the operation it was found that a host was using too many SCSI reservations, leading to vmfs performance degradation. What method can be used to eliminate the root cause of SCSI reservation conflicts? (Multiple choice.)
- Reduce the number of snapshots.
- Reduce the number of virtual machines per LUN.
- Increase the number of LUNs and limit the number of hosts accessing the same LUN.
- Change the type of virtual disk created.
-
What value can the HP UN order lvextend-m parameters be set? (Multiple choice.)
- 0
- 1
- 2
- Unlimited
-
Oracle database normally starts the opening state of the process. Which files must it read? (Multiple choice.)
- Parameter file
- Control Documents
- Archive log file
- Data files
-
What are the common high-risk operations with Linux? (Multiple choice.)
- rm delete file operation
- mkfs. ext3 format file system operation
- dd command
- Continue to write new data to the file system after the file system is damaged
-
Which description of the N8000 Clustered NAS file system snapshot features and their application is wrong?
- Snapshot file system can be dedicated as a separate space to the client.
- For a file system can create multiple snapshots, support snapshots of the snapshot
- Snapshot file system provides only read-only access to external, it cannot provide write operations
- File System Snapshot Instantly copy the source file system completely available copy, when due to viruses or man-made misuse and other causes of the original file system is not available, the rollback of the snapshot can restore the original file system.
-
For commonly used SQL server 2005 and 2008, users can connect to a specific service through the SQL server management studio tool database engine. T login there are two ways to authenticate. Which mode is needed for the client application connection?
- sql server authentication
- Windows authentication
- Log in as super user
- Other ways when landing
-
Huawei Oceanstor 900 adopts erasure code technology to protect the data. If an office has six nodes, and the customer wants to have one office, what redundancy model protection level can be used? (Multiple choice.)
- 4 + 3: 1
- 6 + 3
- 4 + 2
- 12 + 3: 1
-
Which command will modify vg01 into vg – app without affecting the HPUX 11.31 system volume group?
- can not sit down
- vgchange
- vgexport mkdir mknod vgimport
- vgremove mkdir mknod vgcreate
-
When the database is protected and the virtual snapshots are used from the end to verify LUN data consistency on the production end and the disaster recovery end. However, the disaster recovery end of the LUNd database can not be started normally. What is the possible reason? (Multiple choice.)
- After a snapshot of the LUN of the redundancy site is created, the snapshot is not activated at the same time.
- Disaster recovery storage side of the database resides in the cache has not been written to the hard disk.
- When creating a snapshot on the disaster recovery end LUN, the production end is copying data to the disaster recovery end.
- The production end and disaster recovery end adopt the disaster recovery solution of incremental LUN copy. The incremental data is abnormally interrupted during the synchronization process and has not been repaired.
-
RAID2.0 has the natural advantage of supporting a smart tier, to accelerate the performance of hot data. Which of the following descriptions about the smart tier performance is correct?
- When smart LUNs act as backup media, smart tier’s performance improvement on this LUN is not obvious.
- During the running of the business, the extent size can be adjusted by the size of the hotspot area to obtain better performance.
- Literacy ratio in the 1:9 scenario, enabling the smart tier has greatly improved the performance of the business.
- Smart tier has no effect on host performance during hot data migration.
-
In the OceanStor 18000 storage system, a 15K RPM SAS disk is used. Assuming that the average seek latency of this type of disk is 6 ms. which type of disk can provide a single disk IOPS?
- 100
- 150
- 125
- 167
-
Huawei OceanStor storage controller BBUs are both in a fault alarm. Which description is correct for the upper application?
- System does not work.
- If the device is powered off unexpectedly, some of the business data will be lost.
- Business performance is not affected.
- Upper business IO read and write will not have any impact.
-
The client environment is the HP-UX11i v2 operating system, the HBA is the AD193A, and the operating system comes with the driver. The storage array is Huawei OceanStor V3. When the LUN mapping between HP-UX and the storage system is completed, you can not change the topology mode of the FC host interface card on the storage system.
- True
- False
-
In an HPUX system, you use the lv image lvreduce or lvsplit command / dev / vg01 / lv – test within a mirror. Which command will test the implementation of the following command lvsplist / dev / vg01 / lv -, using vgdisplay-v system to see what the lv is.
- LV-test
- lv-testa
- lv-testb
- lv-testbackup
-
What is correct about the reconstruction of the Huawei OceanStor V3 storage system? (Multiple choice.)
- It can quickly recover valid data, not updated data does not need to be restored.
- Complete reconstruction requires data difference log information.
- Recovery Refactoring uses a scenario where the disk can not be used for downgrade.
- In the event of a sudden disk failure recovery reconstruction.
-
A user performs the following operations on an OceanStor 9000:
1. Create a user group named Group01 and sets a quota for Group01 in the /home/aroup0t directory as follows:
Recommended threshold: 10 GB
Soft threshold: 15 GB.
Grace period: 10 days
Hard threshold: 20 6B
2. Create a user account named User01 in Group01 and sets a quota for User01 in the /home/group01 directory as follows:
Recommended threshold: 8 GB
Soft threshold: 18 GB
Grace period: 15 days
Hard threshold: 25 68Which quota applies to User01 in the /home/group01 directory?
- Recommended threshold: 10 GB
Soft threshold: 15 GB
Grace period: 10 days
Hard threshold: 20 GB - Recommended threshold: 10 GB
Soft threshold: 18 GB
Grace period: 15 days
Hard threshold: 20 GB - Recommended threshold: 8 GB
Soft threshold: 18 GB
Grace period: 15 days
Hard threshold: 25 GB - Recommended threshold: 8 GB
Soft threshold: 15 GB
Grace period: 10 days
Hard threshold: 20 GB
- Recommended threshold: 10 GB
-
A TV station plans to adopt Huawei OceanStor 9000 as a back-end storage system, with 10 OceanStor 9000 C nodes, planned to be deployed in 4 standard cabinets, with all backends connected to a pair of stacked back-end CE6850 switches. There is no single customer in the existing networking standalone management network. Which of the network IP address planning described below is incorrect?
- You can plan back-end storage network for 9000 internal communications, without planning gateway address, and front-end network with the same network segment IP address.
- Oceanstor 9000 front-end network and management network can be considered together, planning for the same network segment.
- Back-end CE6850 switches need to use four stacked cables for stacking connection to ensure bandwidth requirements
- The external NTP server address and the OceanStor 9000 front-end network need to communicate to ensure that the OceanStor 9000 system and client applications maintain time synchronization.
-
Which of the following is not a disaster recovery manual restart configuration necessary to restore the production system (Multiple choice.)
- Stop the current production business
- Add the remote device to the original production array
- With the disaster recovery array as the master LUN and the original production array as the slave LUN, create the remote replication relationship between the DR and the production end and wait for the initial synchronization to be completed.
- Make an incremental synchronization.
- Delete the original production array consistency group.
Subscribe